threaddash12
threaddash12
0 active listings
Last online 4 months ago
Registered for 4+ months
Send message All seller items (0) www.selleckchem.com/products/cm-4620.html
About seller
Client performance directs clinical decisions, and the clinician adapts treatment components in order to facilitate functional change. Conclusion We provide a case example of an adolescent client treated in our university clinic to demonstrate the implementation of the proposed personalized and dynamic approach to PCS management.Artificial intelligence (AI) applications, in the form of machine learning and deep learning, are being incorporated into practice in various aspects of medicine, including radiation oncology. Ample evidence from recent publications explores its utility and future use in external beam radiotherapy. However, the discussion on its role in brachytherapy is sparse. This article summarizes available current literature and discusses potential uses of AI in brachytherapy, including future directions. AI has been applied for brachytherapy procedures during almost all steps, starting from decision-making till treatment completion. AI use has led to improvement in efficiency and accuracy by reducing the human errors and saving time in certain aspects. Apart from direct use in brachytherapy, AI also contributes to contemporary advancements in radiology and associated sciences that can affect brachytherapy decisions and treatment. There is a renewal of interest in brachytherapy as a technique in recent years, contributed largely by the understanding that contemporary advances such as intensity modulated radiotherapy and stereotactic external beam radiotherapy cannot match the geometric gains and conformality of brachytherapy, and the integrated efforts of international brachytherapy societies to promote brachytherapy training and awareness. Use of AI technologies may consolidate it further by reducing human effort and time. Prospective validation over larger studies and incorporation of AI technologies for a larger patient population would help improve the efficiency and acceptance of brachytherapy. The enthusiasm favoring AI needs to be balanced against the short duration and quantum of experience with AI in limited patient subsets, need for constant learning and re-learning to train the AI algorithms, and the inevitability of humans having to take responsibility for the correctness and safety of treatments. To compare radiation dose and image quality of single-energy (SECT) and dual-energy (DECT) head and neck CT examinations performed with second- and third-generation dual-source CT (DSCT) in matched patient cohorts. 200 patients (mean age 55.1 ± 16.9 years) who underwent venous phase head and neck CT with a vendor-preset protocol were retrospectively divided into four equal groups ( = 50) matched by gender and BMI second (Group A, SECT, 100-kV; Group B, DECT, 80/Sn140-kV), and third-generation DSCT (Group C, SECT, 100-kV; Group D, DECT, 90/Sn150-kV). Assessment of radiation dose was performed for an average scan length of 27 cm. Contrast-to-noise ratio measurements and dose-independent figure-of-merit calculations of the submandibular gland, thyroid, internal jugular vein, and common carotid artery were analyzed quantitatively. Qualitative image parameters were evaluated regarding overall image quality, artifacts and reader confidence using 5-point Likert scales. Effective radiation dose (ED) was not sse and image quality of standard SECT and DECT protocols of second- and third-generation DSCT platforms.Differences in radiation dose between SECT and DECT of the dose-vulnerable head and neck region using DSCT systems have not been evaluated so far. Therefore, this study directly compares radiation dose and image quality of standard SECT and DECT protocols of second- and third-generation DSCT platforms. Breast cancer radiotherapy is increasingly delivered supine with multiple, short breath-holds. There may be heart and lung sparing advantages for locoregional breast cancer of both prone treatment and in a single breath-hold. We test here whether single prolonged breath-holds are possible in the prone, front crawl position. 19 healthy volunteers were trained to deliver supine, single prolonged breath-holds with pre-oxygenation and hypocapnia. We tested whether all could achieve the same durations in the prone, front crawl position. 19 healthy volunteers achieved supine, single prolonged breath-holds for mean of 6.2 ± 0.3 min. All were able to hold safely for the same duration while prone (6.1 ± 0.2 min . by paired ANOVA). With prone, the increased weight on the chest did not impede chest inflation, nor the ability to hold air in the chest. Thus, the rate of chest deflation (mean anteroposterior deflation movement of three craniocaudally arranged surface markers on the spinal cord) was the same (1.2 ± 0.2, 2.0 ± 0.4 and 1.2 ± 0.4 mm/min) as found previously during supine prolonged breath-holds. No leakage of carbon dioxide or air was detectable into the facemask. Single prolonged (>5 min) breath-holds are equally possible in the prone, front crawl position. Prolonged breath-holds in the front crawl position are possible and have the same durations as in the supine position. Such training would therefore be feasible for some patients with breast cancer requiring loco-regional irradiation. It would have obvious advantages for hypofractionation.Prolonged breath-holds in the front crawl position are possible and have the same durations as in the supine position. Such training would therefore be feasible for some patients with breast cancer requiring loco-regional irradiation. It would have obvious advantages for hypofractionation.Aortic stenosis (AS) remains one of the most common forms of valve disease, with significant impact on patient survival. The disease is characterized by left ventricular outflow obstruction and encompasses a series of stenotic lesions starting from the left ventricular outflow tract to the descending aorta. Obstructions may be subvalvar, valvar, or supravalvar and can be present at birth (congenital) or acquired later in life. Bicuspid aortic valve, whereby the aortic valve forms with two instead of three cusps, is the most common cause of AS in younger patients due to primary anatomic narrowing of the valve. Zegocractin price In addition, the secondary onset of premature calcification, likely induced by altered hemodynamics, further obstructs left ventricular outflow in bicuspid aortic valve patients. In adults, degenerative AS involves progressive calcification of an anatomically normal, tricuspid aortic valve and is attributed to lifelong exposure to multifactoral risk factors and physiological wear-and-tear that negatively impacts valve structure-function relationships.

threaddash12's listings

User has no active listings
Are you a professional seller? Create an account
Non-logged user
Hello wave
Welcome! Sign in or register