About seller
Based on the clinical application data of medical X-ray computed tomography (CT) in the Shanghai Sixth People's Hospital, this study transformed it into the product reliability index requirements, and took the mechanical representative component-examination table (hereinafter referred to as "patient table") and the electronic representative component-DCB (data control board) as examples. Based on the relationship between failure characteristics and clinical application data, a complete set of closed-loop implementation methods from reliability index requirements to reliability design and verification are discussed.In this study, through the analysis of the composition of domestic large radioactive medical equipment PET/CT and the characteristics of each subsystem, combing the vulnerable spots, according to the standard requirements of PET/CT for 10 years in its service life, we research the PET/CT service life's effectiveness. Firstly, this study introduces the concept of service life, the relationship between service life and risk analysis, the pivotal system composition of PET/CT, the importance of reliability of each component, the traditional test method to verify its reliability is researched. This study suggests a test procedure and method to prove the reliability of various components of PET/CT equipment during the service life. This method is described in detail, and the specific test process in practical engineering application is discussed, which proves that it is beneficial to ensure the effectiveness of PET/CT during the service life.Fetal heart rate plays an essential role in maternal and fetal monitoring and fetal health detection. In this study, a method based on Poincare Plot and LSTM is proposed to realize the high performance classification of abnormal fetal heart rate. Firstly, the original fetal heart rate signal of CTU-UHB database is preprocessed via interpolation, then the sequential fetal heart rate signal is converted into Poincare Plot to obtain nonlinear characteristics of the signals, and then SquenzeNet is used to extract the features of Poincare Plot. Finally, the features extracted by SqueezeNet are classified by LSTM. And the accuracy, the true positive rate and the false positive rate are 98.00%, 100.00%, 92.30% respectively on 2 000 test set data. Compared with the traditional fetal heart rate classification method, all respects are improved. The method proposed in this study has good performance in CTU-UHB fetal monitoring database and has certain practical value in the clinical diagnosis of auxiliary fetal heart rate detection.In neurosurgery, skull repair caused by surgical approach is one of the important research contents. In this paper, a rapid reconstruction method of the skull defect with optical navigation system is proposed. This method can automatically reconstruct the structure of skull defect with the intraoperative defect edge points and preoperative medical image data. The head model experiment was used to evaluate the effect of the method, the average error of the reconstruction of the defect in the right orbit was 0.424 mm, while the average error of the reconstruction of the defect in the posterior skull base was 0.377 mm. The experimental results show that the structure of the defect is consistent with the actual defect, and the reconstruction accuracy satisfies the clinical requirements in neurosurgery.Aiming at the problem of timeliness of CBCT reconstruction, a CBCT fast short scan reconstruction method is proposed. At the same time, the image reconstruction process in which a new attenuation compensation algorithm is applied to improve image quality. When performing FDK three-dimensional reconstruction of a single-frame acquisition image, the Parker-weighted image is calculated in real time, and a new attenuation compensation algorithm is applied in the back projection process to complete the short scan Parker-weighted reconstruction. This method simulates the CBCT synchronous acquisition and reconstruction process by establishing collection and reconstruction threads. Under the premise of satisfying the reconstruction quality, the reconstruction can be completed within 1 to 2 seconds after the patient collection is completed, which achieves the purpose of real-time.Patient experience in healthcare has long been recognised in the UK and internationally as a crucial benchmark for assessing quality of care in healthcare settings. It is increasingly becoming part of a nurse's role to conduct, analyse and present the findings of patient satisfaction audits and research projects, and to implement changes to services based on the data collected. To undertake these audits and projects effectively, nurses require knowledge of how to use various data collection methods and research tools, determine their validity and reliability, and minimise bias. This article provides information about these areas, with the aim of assisting nurses in designing and implementing patient satisfaction audits and research projects in their clinical area, which can subsequently be used to improve patient experience.Angiotensin-converting enzyme II (ACE2) in association with type II transmembrane serine protease (TMPRSS2) is considered the main receptor of SARS-CoV-2. However, considering the clinical complications of COVID-19 in different organs, there is no strong association between the abundance of ACE2/TMPRSS2 co-expression and clinical features of the disease and the severity of complications. Since SARS-CoV-2 affects certain organs that lack or have low expression of ACE2/TMPRSS2, it may be possible that the virus employs other receptors for colonization and entry. Based on recent studies, glucose-regulated protein 78 (GRP78) can be a potential alternative receptor for SARS-CoV-2 entry. In this letter, supporting evidence proposed GRP78 as an alternative receptor in SARS-CoV-2 infection. Circular RNA (circRNA) is of significant interest in genetic research. The aim of this study was to assess global trends in circRNA research production in order to shed new light on future research frontiers. In this retrospective study, we conducted a literature search using the Web of Science Core Collection (WoSCC) database on March 21, 2019 to retrieve publications from 2007 to 2018. Excel 2013, CiteSpace V, and VOSviewer were used to evaluate bibliometric features that included publication output, countries/regions, institutions, journals, citation frequency, H-index, and research hotspots. Global cumulative publication output on circRNA consisted of 998 papers with a total citation of 28 595 during 2007-2018. China, the US, and Germany were the most prolific countries. anti-IL-6R inhibitor China ranked first in H-index (60 times) and citations (13 333 times). The most productive institution was Nanjing Medical University with 73 papers. Biochemical and Biophysical Research Communications (impact factor [IF]20172.559) ranked first among journals in the number of publications (64 papers).