About seller
The results suggest that Dnm3os silencing may affect the process of cardiac fibroblast activation by inhibiting TGF-β1/Smad2/3 signal pathway. Therefore, interfering with the expression of lncRNA Dnm3os may be a potential target for the treatment of cardiac fibrosis.The medical literature contains a wealth of valuable medical knowledge. At present, the research on extraction of entity relationship in medical literature has made great progress, but with the exponential increase in the number of medical literature, the annotation of medical text has become a big problem. In order to solve the problem of manual annotation time such as consuming and heavy workload, a remote monitoring annotation method is proposed, but this method will introduce a lot of noise. In this paper, a novel neural network structure based on convolutional neural network is proposed, which can solve a large number of noise problems. The model can use the multi-window convolutional neural network to automatically extract sentence features. After the sentence vectors are obtained, the sentences that are effective to the real relationship are selected through the attention mechanism. In particular, an entity type (ET) embedding method is proposed for relationship classification by adding entity type characteristics. The attention mechanism at sentence level is proposed for relation extraction in allusion to the unavoidable labeling errors in training texts. We conducted an experiment using 968 medical references on diabetes, and the results showed that compared with the baseline model, the present model achieved good results in the medical literature, and F1-score reached 93.15%. Finally, the extracted 11 types of relationships were stored as triples, and these triples were used to create a medical map of complex relationships with 33 347 nodes and 43 686 relationship edges. Experimental results show that the algorithm used in this paper is superior to the optimal reference system for relationship extraction.This study aims to overcome the shortcomings such as low efficiency, high cost and difficult to carry out multi-parameter research, which limited the optimization of infusion bag configuration and manufacture technique by experiment method. We put forward a fluid cavity based finite element method, and it could be used to simulate the stress distribution and deformation process of infusion bag under external load. In this paper, numerical models of infusion bag with different sizes was built, and the fluid-solid coupling deformation process was calculated using the fluid cavity method in software ABAQUS subject to the same boundary conditions with the burst test. The peeling strength which was obtained from the peeling adhesion test was used as failure criterion. The calculated resultant force which makes the computed peeling stress reach the peeling strength was compared with experiment data, and the stress distribution was analyzed compared with the rupture process of burst test. The results showed that considering the errors caused by the difference of weak welding and eccentric load, the flow cavity based finite element method can accurately model the stress distribution and deformation process of infusion bag. It could be useful for the optimization of multi chamber infusion bag configuration and manufacture technique, leading to cost reduction and study efficiency improvement.The rotation center of traditional hip disarticulation prosthesis is often placed in the front and lower part of the socket, which is asymmetric with the rotation center of the healthy hip joint, resulting in poor symmetry between the prosthesis movement and the healthy lower limb movement. Besides, most of the prosthesis are passive joints, which need to rely on the amputee's compensatory hip lifting movement to realize the prosthesis movement, and the same walking movement needs to consume 2-3 times of energy compared with normal people. This paper presents a dynamic hip disarticulation prosthesis (HDPs) based on remote center of mechanism (RCM). Using the double parallelogram design method, taking the minimum size of the mechanism as the objective, the genetic algorithm was used to optimize the size, and the rotation center of the prosthesis was symmetrical with the rotation center of the healthy lower limb. By analyzing the relationship between the torque and angle of hip joint in the process of human walking, the control system mirrored the motion parameters of the lower on the healthy side, and used the parallel drive system to provide assistance for the prosthesis. Based on the established virtual prototype simulation platform of solid works and Adams, the motion simulation of hip disarticulation prosthesis was carried out and the change curve was obtained. Selleckchem 2-DG Through quantitative comparison with healthy lower limb and traditional prosthesis, the scientificity of the design scheme was analyzed. The results show that the design can achieve the desired effect, and the design scheme is feasible.The subpulmonary ventricular exclusion (Fontan) could effectively improve the living quality for the children patients with a functional single ventricle in clinical. However, postoperative Fontan circulation failure can easily occur, causing obvious limitations while clinically implementing Fontan. The cavopulmonary assist devices (CPAD) is currently an effective means to solve such limitations. Therefore, in this paper the in-silico and in-vitro experiment coupled model of Fontan circulation failure for the children patients with a single ventricle and CPAD is established to evaluate the effects of CPAD on the Fontan circulation failure. Then a sensorless feedback control algorithm is proposed to provide sufficient cardiac output and prevent vena caval suction due to CPAD constant pump speed. Based on the CPAD pump speed-an intrinsic parameter, the sensorless feedback control algorithm could accurately estimate the cavopulmonary pressure head (CPPH) using extended Kalman filter, eliminating the disadvantage for pressure sensors that cannot be used in long term. And a gain-scheduled, proportional integral (PI) controller is used to make the actual CPPH approach to the reference value. Results show that the CPAD could effectively increase physiological perfusion for the children patients and reduce the workload of a single ventricle, and the sensorless feedback control algorithm can effectively guarantee cardiac output and prevent suction. This study can provide theoretical basis and technical support for the design and optimization of CPAD, and has potential clinical application value.