The Revo NX is a new optical biometer, based on spectral domain optical coherence tomography and able to obtain high-definition scans of both the anterior and posterior segment of the eye. A previous study found that its measurements of axial length (AL) were not interchangeable with those provided by a validated optical biometer, so that the manufacturer updated the instrument to improve agreement of AL values. This study aimed to prospectively compare the measurements by the updated Revo NX (ver 9.5.0, Biometry module) to those by two validated devices, the IOLMaster 700 and Lenstar LS-900. Optopol Technologies, Zawiercie, Poland DESIGN Prospective evaluation of diagnostic test. Comparison between the devices was performed using repeated measures analysis of variance (ANOVA) with Bonferroni post-test, correlation coefficients and the Bland-Altman method. The investigation evaluated the results of 63 patients. For AL, anterior chamber depth (ACD) and lens thickness (LT) the differences were not clinically significant, as they were less than 0.01 mm. Repeated measures ANOVA, however, detected a statistically significant difference for AL (p<0.0001) and central corneal thickness (p<0.0001), but not for ACD (p=0.0630) or LT (p=0.2667). The results obtained with all three biometers manifested a high level of agreement in the Bland-Altman analysis and very strong correlation. The measurements by the updated Revo NX had high agreement with the other optical biometers; a clear improvement was detected with respect to the previous analysis between the original Revo NX (ver 8.0.3) and the Lenstar LS-900.The measurements by the updated Revo NX had high agreement with the other optical biometers; a clear improvement was detected with respect to the previous analysis between the original Revo NX (ver 8.0.3) and the Lenstar LS-900.Small incision lenticule extraction (SmILE) is a stromal based, flapless, minimally invasive form of laser vision correction for the treatment of myopia and myopic astigmatism. SmILE surgery is a more technical procedure compared to other refractive surgeries and generally has a longer skill mastery acquisition period. Thus far, no novel stabilization devices or techniques have been proposed. To rectify this, we introduce a novel distal corneal countertraction device for SmILE surgery, the Monson SmILE Fixation Device (MSFD). This device provides reliable corneal and globe stabilization during delamination and lenticular dissection. It may minimize tissue distortion and manipulation, simplify lenticule dissection, and may decrease operation times and improve cosmesis. Countertraction can also easily be adjusted throughout the procedure. To compare the dynamics of axial intraocular lens (IOL) position and stability in the capsular bag following fellow-eye implanation of a one-piece C-loop and a four-point haptic IOL. Hanusch Hospital, Vienna DESIGN Prospective, comparative, randomised bilateral study METHODS 100 eyes of 50 patients were randomly implanted with a C-loop IOL (CT LUCIA 611P) in one eye and a four-point haptic IOL (CT ASPHINA 409MP) in the other eye. Anterior chamber depth (ACD) was measured one week (W1), one month (M1) and 4-6 months (M4-6) after surgery using a swept source optical coherence tomography device (ZEISS IOLMaster700). Uncorrected distance visual acuity (UDVA), best corrected distance visual acuity (CDVA) and subjective refraction outcomes were assessed at four to six months (M4-6) postop follow-up. Pseudophakia ACD values at W1, M1 and M4-6 time points were significantly different in eyes implanted with the C-loop IOL compared to the four-point haptic IOL (p < 0.001). The overall IOL shift was 0.25±0.16mm for the 4-point haptic and 0.14±0.09mm for the C-loop (p<0.001). M4-6 mean monocular UDVA outcome for C-loop eyes was 0.06 ± 0.14 logMAR and 0.03 ± 0.10 logMAR for 4-point haptic. M4-6 mean spherical equivalent (SE) was - 0.32 ± 0.48 D in the C-loop group and - 0.33 ± 0.42 D in the 4-point haptic group. Significant differences in IOL design results in different postoperative ACD values. No relevant or significant differences were found in refraction or visual acuity between the groups.Significant differences in IOL design results in different postoperative ACD values. No relevant or significant differences were found in refraction or visual acuity between the groups.Corneal allogenic ring segments (CAIRS) are semicircular pieces of donor corneal stroma which may be surgically implanted to flatten keratoconic corneas. Conventionally, these donor segments are inserted into channels created via femtosecond laser dissection. However, access to femtosecond technology is not universal. Here we describe an alternate, manual technique for channel creation which is femtosecond laser independent. To report practice patterns of corneal transplantation in Europe. Corneal clinics in ten European member states, the United Kingdom, and Switzerland. Multinational registry study. Corneal transplant procedures registered in the European Cornea and Cell Transplantation Registry (ECCTR) were identified. We analyzed preoperative donor and recipient characteristics, indication and reason for transplantation, and surgical techniques. 12,913 corneal transplants were identified from ten European Union member states, the United Kingdom (UK) and Switzerland. Most countries were self-sufficient with regard to donor tissue. Fuchs' endothelial corneal dystrophy (FED) was the most common indication (41%, n=5,325), followed by regraft (16%, n=2,108), Pseudophakic bullous keratopathy (PBK, 12%, n=1,594), and keratoconus (12%, n=1,506). Descemet stripping (automated) endothelial keratoplasty (DS[A]EK, 46%, n=5,918) was the most commonly performed technique, followed by Penetrating keratoplasty (PK, 30%, n=3,886), and Descemet membrane endothelial keratoplasty (DMEK, 9%, n=1,838). check details Vision improvement was the main reason for corneal transplantation (90%, n=11,591). Surgical technique and reason for transplantation differed between indications. This report provides the most comprehensive overview of corneal transplantation practice patterns in Europe to date. Fuchs endothelial dystrophy is the most common indication, vision improvement the leading reason, and DS(A)EK the predominant technique for corneal transplantation.This report provides the most comprehensive overview of corneal transplantation practice patterns in Europe to date. Fuchs endothelial dystrophy is the most common indication, vision improvement the leading reason, and DS(A)EK the predominant technique for corneal transplantation.