About seller
Objective The aim of the present study is to evaluate the artery of Adamkiewicz by multidetector computed tomography angiography (MCTA) in a Brazilian population. Methods Two independent observers evaluated 86 coronary MCTA examinations. The variables studied included the identification of the artery of Adamkiewicz at its origin level, and its entry side in the spine. Results The artery of Adamkiewicz was detected in 71 (82.5%) examinations. The origin level was identified between the 9th and 11th thoracic vertebrae (T9 and T11) in 56 (79.2%) patients. In 65 (91.5%) patients, the artery was on the left side. The identification of the artery of Adamkiewicz using MCTA showed high reproducibility. Conclusions Our results were consistent with the literature regarding the identification of the artery of Adamkiewicz using MCTA, suggesting that this technique should be considered as an option to recognize this structure. In addition, we found that the distribution of the artery of Adamkiewicz in the Brazilian population is similar to that of other populations, that is, its most common origin is at the left side, between the 8th and 12th thoracic vertebrae (T8-T12).Objective To determine the anatomical parameters of the atlas (C1) in a sample of the Brazilian population and compare them with the results already presented in the literature for other populations and, thus, to identify and change the indications of implants used in the treatment of the upper cervical spine. Methods We performed a retrospective observational study of a prospective database, including 100 patients seen between January 2012 and December 2013. We used axial and sagittal sections of computed tomography (CT) scans. The parameters studied were; axial distance from posterior tubercle to the screw entry point (DPT_EP), safety angle of the axial screw (SA_AS), ideal axial screw length (_ASL) and distance of the spinal canal from the transverse foramen (DSC_TF); Sagittal ideal sagittal screw length (_SSL), safety angle of the sagittal screw (SA_SS) and posterior arch thickness (_PAT). All of the parameters were divided according to age, gender, and left and right sides. Results The minimum mean point of entry ranged from 20 mm to 22.7 mm. Lurbinectedin RNA Synthesis modulator The average security zone ranged from 18.09° to 23.68°. The mean posterior arch thickness ranged from 7.21 mm to 8.95 mm. The lowest averages were found in females. Using an original and reproducible technique of CT evaluation. Conclusion The anatomical parameters of the atlas found in the sample of the studied population were similar to those previously presented in the literature. However, differences between the sexes were observed.Objective Based on studies regarding pain physiology and its relation to emotional distress conditions, psychological evaluation became essential to determine the most favorable patient profiles to distinct therapeutic approaches. The Distress Risk Assessment Method (DRAM) has been developed as a screening instrument for patients with lumbar pain, classifying them in subgroups as normal, at risk, distressed somatic and distressed depressive, based on the two components of DRAM scores (Modified Somatic Perception Questionnaire [MSPQ] and Zung questionnaires). The objective of the present study is to translate and culturally adapt the DRAM to the Brazilian Portuguese language, and to determine the reliability of the final version. Methods As proposed by the International Quality of Life Assessment (IQOLA) method, a Brazilian Portuguese version of the DRAM has been applied to a sample of 85 individuals from 3 participant centers. Results The results confirmed the reliability and reproducibility of the DRAM in its Brazilian Portuguese final version Cronbach alpha of 0.815 (MSPQ) and 0.794 (Zung) and intraclass correlation coefficient (ICC) of 0.688 (MSPQ) and 0.659 (Zung). Conclusion The presented DRAM version in Brazilian Portuguese is reliable and is available to clinical practice use.Objective To evaluate the clinical and functional results of transforaminal endoscopic lumbar discectomy. Materials and Methods From August 2015 to January 2017, 101 patients with lumbar disc hernia refractory to clinical treatment underwent endoscopic discectomy. Through clinical evaluation by the Visual Analogue Scale and functional evaluation by the Oswestry Disability Index questionnaire, the patients were analyzed in the preoperative period, the immediate postoperative period, at 1 month, 3 months, 6 months and 1 year after surgery. Results The mean age of the participants was 48.1 years. The most affected disc levels were L4-L5 and L5-S1. A total of 29 patients were treated at 2 disc levels. After 1 month of postoperative follow-up, the mean scores on the questionnaires (VAS and ODI) decreased significantly ( p less then 0.001). Conclusion Transforaminal endoscopic Lumbar discectomy has been shown to be a safe, effective and minimally-invasive alternative for the treatment of lumbar disc herniation. The procedure has advantages, such as short hospital stay, surgery performed under local anesthesia and sedation, early return to daily activities, and low rate of complications.Objective The literature entails various intramedullary and extramedullary methods for distal fibula fracture fixation; with no consensus yet over the ideal method of fixation. We have retrospectively analyzed the results of using a twisted and contoured 3.5 mm locking compression plate (LCP) as a posterior buttress plate. Methods Of the 62 cases with ankle fractures managed at our institute by the senior author from 1 st January 2012 to 31 st December 2015, 41 patients met our inclusion criteria (Danis-Weber types B and C). Results All 41 distal fibular fractures healed uneventfully, at a mean of 10.4 weeks (8-14 weeks) (Figs. 6, 7, 8 to 9) with no complications. The mean American Orthopaedic Foot & Ankle Society (AOFAS) score was 92.6 (86-100) at a mean follow-up of 31.5 months (14-61 months). Conclusions We have achieved excellent clinical and radiological outcomes using a twisted 3.5 mm LCP as a posterior buttress by combining the advantages of posterior antiglide plating and lateral LCP.