About seller
The aim of this research study is to develop a queue assessment model to evaluate the inflow of walk-in outpatients in a busy public hospital of an emerging economy, in the absence of appointment systems, and construct a dynamic framework dedicated towards the practical implementation of the proposed model, for continuous monitoring of the queue system. The current study utilizes data envelopment analysis (DEA) to develop a combined queuing-DEA model as applied to evaluate the wait times of patients, within different stages of the outpatients' department at the Combined Military Hospital (CMH) in Lahore, Pakistan, over a period of seven weeks (23rd April to 28th May 2014). check details The number of doctors/personnel and consultation time were considered as outputs, where consultation time was the non-discretionary output. The two inputs were wait time and length of queue. Additionally, VBA programming in Excel has been utilized to develop the dynamic framework for continuous queue monitoring. The inadequate availab vital information in the form of "required" number of personnel which allows the administrators to control the queue pre-emptively minimizing wait times, with optimal yet dynamic staff allocation. Additionally, the dynamic framework specifically targets practical implementation in resource-poor public hospitals of emerging economies for continuous queue monitoring. Spatial frequency domain imaging (SFDI) is an imaging modality that projects spatially modulated light patterns to determine optical property maps for absorption and reduced scattering of biological tissue via a pixel-by-pixel data acquisition and analysis procedure. Compressive sensing (CS) is a signal processing methodology which aims to reproduce the original signal with a reduced number of measurements, addressing the pixel-wise nature of SFDI. These methodologies have been combined for complex heterogenous data in both the image detection and data analysis stage in a compressive sensing SFDI (cs-SFDI) approach, showing reduction in both the data acquisition and overall computational time. Application of CS in SFDI data acquisition and image reconstruction significantly improves data collection and image recovery time without loss of quantitative accuracy. cs-SFDI has been applied to an increased heterogenic sample from the AppSFDI data set (back of the hand), highlighting the increased number of CS measurements required as compared to simple phantoms to accurately obtain optical property maps. A novel application of CS to the parameter recovery stage of image analysis has also been developed and validated. Dimensionality reduction has been demonstrated using the increased heterogenic sample at both the acquisition and analysis stages. A data reduction of 30% for the cs-SFDI and up to 80% for the parameter recover was achieved as compared to traditional SFDI, while maintaining an error of <10 % for the recovered optical property maps. The application of data reduction through CS demonstrates additional capabilities for multi- and hyperspectral SFDI, providing advanced optical and physiological property maps.The application of data reduction through CS demonstrates additional capabilities for multi- and hyperspectral SFDI, providing advanced optical and physiological property maps. Optical coherence tomography (OCT) is widely used as a potential diagnostic tool for a variety of diseases including various types of cancer. However, sensitivity and specificity analyses of OCT in different cancers yield results varying from 11% to 100%. Hence, there is a need for more detailed statistical analysis of blinded reader studies. Extensive statistical analysis is performed on results from a blinded study involving OCT of breast tumor margins to assess the impact of reader variability on sensitivity and specificity. Five readers with varying levels of experience reading OCT images assessed 50 OCT images of breast tumor margins collected using an intraoperative OCT system. Statistical modeling and analysis was performed using the R language to analyze reader experience and variability. Statistical analysis showed that the readers' prior experience with OCT images was directly related to the probability of the readers' assessment agreeing with histology. Additionally, results from readers with prior experience specific to OCT in breast cancer had a higher probability of agreement with histology compared to readers with experience with OCT in other (noncancer) diseases. The results from this study demonstrate the potential impact of reader training and experience in the assessment of sensitivity and specificity. They also demonstrate even greater potential improvement in diagnostic performance by combining results from multiple readers. These preliminary findings suggest valuable directions for further study.The results from this study demonstrate the potential impact of reader training and experience in the assessment of sensitivity and specificity. They also demonstrate even greater potential improvement in diagnostic performance by combining results from multiple readers. These preliminary findings suggest valuable directions for further study. High temporal stability, wavelength independency, and scalable field of view (FOV) are the primary requirements of a quantitative phase microscopy (QPM) system. The high temporal stability of the system provides accurate measurement of minute membrane fluctuations of the biological cells that can be an indicator of disease diagnosis. The main aim of this work is to develop a high temporal stable technique that can accurately quantify the cell's dynamics such as membrane fluctuations of human erythrocytes. Further, the technique should be capable of acquiring scalable FOV and resolution at multiple wavelengths to make it viable for various biological applications. We developed a single-element nearly common path, wavelength-independent, and scalable resolution/FOV QPM system to obtain temporally stable holograms/interferograms of the biological specimens. With the proposed system, the temporal stability is obtained ∼15 mrad without using any vibration isolation table. The capability of the proposed system is first demonstrated on USAF resolution chart and polystyrene spheres (4.